VMware Certified Professional - VMware Cloud Foundation 9.0 Support
Last Update Jan 14, 2026
Total Questions : 60
We are offering FREE 2V0-15.25 VMware exam questions. All you do is to just go and sign up. Give your details, prepare 2V0-15.25 free exam questions and then go for complete pool of VMware Certified Professional - VMware Cloud Foundation 9.0 Support test questions that will help you more.
An administrator logs into the vSphere client to check the health of a cluster. An alert appears on the cluster stating, "vSphere HA host status".
The administrator toggles vSphere HA off and on and the following error appears on the host "A general system error occurred: Failed to start fdm service on host".
What is the cause of this issue?
An administrator is attempting to import a certificate chain In VMware Cloud Foundation (VCF) Operations by uploading a certificate file. The validation fails with an error stating, "The provided certificate content is invalid.'
What is a possible cause for this error?
An administrator is asked to create a second provider gateway (provider gateway 02) in VMware Cloud Foundation (VCF) Automation Region-A.
After launching the Create Provider Gateway workflow in the VCF Automation Provider Management Portal, no Tier-0 Gateway is available for assignment.
How would you resolve this issue?
An administrator is responsible for managing a VMware Cloud Foundation (VCF) Fleet that is configured as follows:
• Single VCF instance with a single workload domain.
• The Workload Domain has a single 5-node VMware vSAN Express Storage Architecture (ESA) cluster.
• The vSAN Default Storage Policy is configured as RAID1.
The administrator is alerted to the fact that storage capacity is running low and, to improve space efficiency, attempts to change the vSAN storage policy on a number of large virtual machines to a 2 Failures - RAID-6 policy.
The policy change is immediately rejected.
What should the administrator do to reduce overall capacity usage while waiting for new storage devices to arrive?
An administrator needs to confirm which account initiates tasks from VMware Cloud Foundation (VCF) Operations. As a test, a virtual machine (VM) is powered on/off through VCF Operations.
In the vCenter task pane, what account would be the initiator of the task?
An administrator has successfully created a new Organization for All Apps In VMware Cloud Foundation (VCF) Automation. When logging into the new organization using the first user account, only the Overview tab is visible.
What is a possible cause of this issue?
An administrator is automating the deployment of a new VMware Cloud Foundation (VCF) fleet using VCF Installer. The VCF fleet must include VCF Automation being deployed in a simple deployment model.
The administrator creates a JSON file, but during the installation attempt the VCF Installer returns an error indicating that the JSON validation has failed.
What is the cause of the errors?
An administrator has been tasked with deploying a new workload domain consisting of six VMware ESX hosts with VMware vSAN into an existing VMware
Cloud Foundation (VCF) instance. After starting the deployment from VCF Operations, they discover that only four of the six hosts required are listed for
selection in the UI. The administrator checks the Unassigned Host Inventory view in the vSphere Client and confirms that all six hosts are listed.
Which step should the administrator perform to identify why the two hosts are not available for selection?
An administrator has been tasked with the deletion of a workload domain within a VMware Cloud Foundation (VCF) instance. The following information has been provided:
• There are two workload domains and a management domain within the VCF instance.
• There is a single vSphere cluster within the workload domain to be deleted.
• There are no user created Virtual Machines in the workload domain cluster.
When performing the deletion in VCF Operations, the task fails at the Gather input for deletion of NSX component stage. The administrator checks the details of the failed task and notices the cause of the error is stated as Cannot read the array length because "
What could be the possible cause of this error message?
An administrator attempts to add a new user (provideradmin05) within the VMware Cloud Foundation (VCF) Automation Provider Management Portal, however provideradmin05 cannot be found for import.
The following information is provided:
• The existing VCF Fleet uses VMware Identity Broker (VIDB) for single sign-on.
• VIDB uses Active Directory as the identity provider.
• A group named VCFA_ProviderAdmins was created in Active Directory, populated with the appropriate user accounts and synchronized with VIDB.
• Five days later provideradmin05 was added to VCFA_ProviderAdmins.
What will resolve this issue?
An administrator discovers that a VMware Cloud Foundation (VCF) workload domain four-node vSAN cluster is experiencing a network partition. The workload domain vCenter displays a "vSAN duster partition" warning. The performance across the cluster is degraded and the objects are showing as non-compliant.
What could be causing the network partition?
An administrator wants to expand a VMware vSAN cluster in a workload domain by adding an unassigned host from the vSphere client. However, at the Host Selection screen no hosts are available and the following message displayed:
No unassigned hosts available with storage type VSAN. Commission hosts with physical NICs 0 & 1 to Add Host from UI.
How can the administrator commission hosts?
An administrator has received reports of high CPU ready times on several Virtual Machines (VMs) running within a VMware Cloud Foundation (VCF) workload domain and has been tasked with collecting detailed metrics for all running Virtual Machines from each ESX host.
Which command line utility will enable the administrator to collect the required metrics?
An administrator is attempting to troubleshoot why the vSAN witness node cannot form a stretched cluster with the vSAN data nodes. The administrator can successfully ping the vSAN data node from the vSAN witness using the following command:
vmkping -I
What could be the possible cause of the issue?
An Administrator has been tasked with creating a new VMware Cloud Foundation (VCF) Automation Region named Region-2. The following information has been provided:
• The current environment has two workload domains named WLD1 and WLD2.
• The workload domains share one NSX Local Manager deployment.
• A VCF Automation Region named region-1 exists that uses the shared NSX Local Manager deployment.
When creating the second Region in VCF Automation, the administrator sees "No results" when attempting to select a NSX Local Manager for the Region. What should the Administrator do to resolve this issue?
An administrator is responsible for supporting a VMware Cloud Foundation (VCF) fleet and has been tasked with deploying VMware Cloud Foundation (VCF) Operations for Logs. To complete this task, the administrator needs to configure a new offline depot within VCF Operations fleet management.
The following information has been provided to the administrator to complete the task:
• Offline Depot Type: Webserver
• Repository URL: http://10.138.148.160/depot/
• Username: depotuser
• Password: P@sswordl23!
• Accept imported certificate: True
When the administrator attempts to configure the depot, the following error message is presented:
Either the depot URL provided is partial or invalid or not reachable or download token is invalid. Check logs for more details.
The administrator completes the following troubleshooting steps:
• Confirms the Repository URL is valid by connecting to it through a web browser.
• Reviews the command used to create the depot:

• Confirms that the downloaded folder and files were copied into the /depot shared folder on the web server hosting the repository
Which two actions must the administrator take to resolve the issue? (Choose two.)
An administrator creates a tag for a virtual machine (VM) in VMware Cloud Foundation (VCF) Operations. When assigning the tag to the virtual machine In vCenter, the tag was not found.
What is the cause of this error?
An administrator is tasked with replacing a VMware vCenter certificate in VMware Cloud Foundation (VCF) Operations with an external CA-signed certificate. The certificate import completes successfully but when running the certificate replacement task, it fails with the following error: Certificate replacement has failed...The Certificate Chain validation failed due to 'Signature does not match' What is the possible cause of this issue?