Labour Day Special 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: exams65

RecoverPoint Specialist Exam for Implementation Engineers Question and Answers

RecoverPoint Specialist Exam for Implementation Engineers

Last Update May 5, 2024
Total Questions : 200

We are offering FREE E20-375 EMC exam questions. All you do is to just go and sign up. Give your details, prepare E20-375 free exam questions and then go for complete pool of RecoverPoint Specialist Exam for Implementation Engineers test questions that will help you more.

E20-375 pdf

E20-375 PDF

$35  $99.99
E20-375 Engine

E20-375 Testing Engine

$42  $119.99
E20-375 PDF + Engine

E20-375 PDF + Testing Engine

$56  $159.99
Questions 1

A Consistency Group consists of one production copy, one local copy, and two remote copies.

How many journals are required for this configuration?

Options:

A.  

Four in total

B.  

Two in total

C.  

One for each remote copy and one for the local copy

D.  

One for the production and one for each remote copy

Discussion 0
Questions 2

You are working on a RecoverPoint local replication solution in an environment that includes VNX and VMAX storage arrays. You want to create a Consistency Group (CG) for your Oracle database. However, some of the database volumes are located in the VNX and others are located in the VMAX.

What is the recommended management solution?

Options:

A.  

Create one CG using VNX and VMAX volumes

B.  

Create a new RecoverPoint cluster and add the VNX splitter

C.  

Migrate all LUNs to the VMAX

D.  

Create two CGs: one for VNX volumes and another for VMAX volumes

Discussion 0
Questions 3

A large data center is hosting storage protection solutions for multiple companies. This solution is accomplished by the hosting organization's ability to consolidate data to an environment with two VNX arrays.

How many RecoverPoint clusters can be used in this environment?

Options:

A.  

12 clusters, assuming each LUN is attached to only one cluster at a time

B.  

6 clusters, assuming only vRPAs are used

C.  

12 clusters, assuming each LUN is replicated across the clusters

D.  

6 clusters, assuming each LUN is attached to only one cluster at a time

Discussion 0
Questions 4

Which three methods are supported for sending system alerts to EMC?

Options:

A.  

FTPS, SMTP, and ESRS

B.  

FTP, SMTP, and ESRS

C.  

SMTPS, FTPS, and ESRS

D.  

HTTPS, SMTP, and ESRS

Discussion 0
Questions 5

You are a storage administrator tasked with creating a Consistency Group in a RecoverPoint/EX system. You launch the Protect Volumes wizard in Unisphere and notice that the desired production volume is not available.

What would be a possible cause?

Options:

A.  

The production volumes are on a non-licensed array.

B.  

The volumes are masked to a host.

C.  

The journal volumes are on a non-licensed array.

D.  

Consistency Groups can only be created by boxmgmt.

Discussion 0
Questions 6

Which tool do you need in order to run the save_settings command from a Windows command prompt?

Options:

A.  

PLink

B.  

PuTTY

C.  

CuteFTP

D.  

WinSCP

Discussion 0
Questions 7

A company has a DR site connected using a 4 Gbps FC link and two RPAs on the primary site, and two RPAs at the DR site. They are experiencing high load events although the FC link is not fully utilized.

What would be the best solution to get the FC link utilization up as high as possible?

Options:

A.  

Add two RPAs to the primary site and add two RPAs to the DR site

B.  

Add two RPAs to the primary site only

C.  

Use distributed consistency groups with one primary RPA and two secondary RPAs on the primary site

D.  

Add two RPAs to the DR site only

Discussion 0
Questions 8

What zoning must be created in the fabric when implementing a VMAX splitter?

Options:

A.  

Separate server-to-storage, RPA-to-RPA, and RPA-to-storage zones

B.  

Separate VSANs and zones for the front-end and back-end devices

C.  

Separate RPA-to-RPA and RPA-to-server zones

D.  

Multiple VSANs with a zone per RPA and front end-devices

Discussion 0
Questions 9

Which EMC storage does RecoverPoint leverage for Snap-based Replication?

Options:

A.  

VNX only

B.  

VMAX only

C.  

VPLEX

D.  

VNX and VMAX

Discussion 0
Questions 10

What is the maximum number of copies supported using the MetroPoint topology for VPLEX continuous data replication?

Options:

A.  

3

B.  

4

C.  

5

D.  

8

Discussion 0
Questions 11

In a EMC RecoverPoint environment, which EMC product adds support for heterogeneous storage systems?

Options:

A.  

VPLEX

B.  

VNX/CX

C.  

VMAX

D.  

Isilon

Discussion 0
Questions 12

Which EMC storage technologies are supported with EMC RecoverPoint?

Options:

A.  

VNX, VMAX, and VPLEX

B.  

VNX, Data Domain, and Isilon

C.  

VMAX, VPLEX, and Data Domain

D.  

VPLEX, Isilon, and VNX

Discussion 0
Questions 13

A company is currently using RecoverPoint/CL with CLARiiON CXs in their environment. All of the data has been migrated to new VNXs and the CX splitters need to be removed from RecoverPoint.

How is this accomplished?

Options:

A.  

In Unisphere for RecoverPoint, navigate to RPA Clusters > RPA-Cluster-Name tab > Splitters and remove the CX splitters

B.  

In Unisphere for RecoverPoint, navigate to RPA Clusters > Splitters and remove the CX splitters

C.  

Use RecoverPoint Deployment Manager to remove the CX splitters

D.  

The CXs will not be detected by Unisphere and the splitter entries will be removed automatically

Discussion 0
Questions 14

Which RecoverPoint features are supported on physical and virtual RPAs?

Options:

A.  

Deduplication, SRM integration, and Snapshot-Based Replication

B.  

Distributed CGs, Deduplication, and SRM integration

C.  

SRM integration, Snapshot-Based Replication, and Distributed CGs

D.  

Snapshot-Based Replication, Distributed CGs, and Deduplication

Discussion 0
Questions 15

Which ports from a VPLEX Metro system must be zoned to the RPAs in order to install the VPLEX write splitter?

Options:

A.  

FE and BE ports

B.  

FE ports only

C.  

BE ports only

D.  

FA ports

Discussion 0
Questions 16

A company is using an EMC VNX storage array. RecoverPoint is being configured to replicate to a DR site. RP will be protecting three datastores:

  • A thick 100 GB LUN containing 60 GB of data
  • A thin 50 GB LUN containing 15 GB of data
  • A thick 75 GB LUN containing 75 GB of data

How much of the user data is being replicated to the DR site?

Options:

A.  

150

B.  

185

C.  

190

D.  

225

Discussion 0
Questions 17

When RecoverPoint is deployed with a VMAX splitter, what presents the virtual target and virtual remote devices?

Options:

A.  

RPAs

B.  

VMAX

C.  

Switch

D.  

Gatekeepers

Discussion 0
Questions 18

During a failover event, you have determined that the last bookmark had corrupted data. What is the fastest way to find the last good replica?

Options:

A.  

Fail back to the primary and create a new replica

B.  

Complete the failover and restore the data from the local backup

C.  

Create a new bookmark and use the Test a Copy wizard

D.  

Move to the previous point in time

Discussion 0
Questions 19

An existing RecoverPoint/CL environment consists of one cluster at the main office and two off-site DR clusters. You have been asked to expand the environment to the maximum number of DR sites using RecoverPoint.

How many additional clusters could be added to this RecoverPoint Environment?

Options:

A.  

2

B.  

4

C.  

5

D.  

8

Discussion 0
Questions 20

After expanding to include an additional existing RecoverPoint cluster you use Deployment Manager to connect the clusters, but it fails.

What might be the problem?

Options:

A.  

New cluster has existing Consistency Group

B.  

RPAs at second cluster are not same type

C.  

Second cluster not yet added to the Repository

D.  

No splitter added to second cluster

Discussion 0
Questions 21

For optimal performance when presenting gatekeepers for a VMAX splitter, how many FA ports should be used in each port group?

Options:

A.  

4

B.  

8

C.  

12

D.  

16

Discussion 0
Questions 22

After running a log collection, which user should you log in as to download the output file?

Options:

A.  

admin

B.  

monitor

C.  

boxmgmt

D.  

security-admin

Discussion 0
Questions 23

You are using the Test a Copy wizard and have chosen virtual access to test your database upgrade. The image has been mounted to a test host. While testing the database upgrade, the host loses access to the image.

What can you do to avoid this problem in the future?

Options:

A.  

Add more journal capacity

B.  

Add an RPA to the local RecoverPoint cluster

C.  

Re-enable image access

D.  

Mount the image to another host

Discussion 0
Questions 24

A customer has two VMAX arrays and three VNX arrays fronted by an EMC VPLEX. They wish to use RecoverPoint to protect their environment.

How many licenses, and of which type, would be required for their environment?

Options:

A.  

1 EX license

B.  

1 SE license and 2 EX licenses

C.  

5 EX licenses

D.  

6 EX licenses

Discussion 0
Questions 25

A company is currently using RecoverPoint/SE in their environment. They have purchased a VMAX which will be deployed to replace a VNX splitter at one site only.

What must be done before they can use the VMAX with RecoverPoint (RP)?

Options:

A.  

Obtain an updated license that will support RP/EX or RP/CL

B.  

Use Unisphere for RecoverPoint to convert from RP/SE to RP/EX or RP/CL

C.  

Purchase and use a VMAX at the other site

D.  

Deploy an updated splitter on the existing array that will function with the new VMAX splitter

Discussion 0
Questions 26

When registering the RPA with a VNX to enable a VNX splitter for RecoverPoint, what failover mode must be set on the VNX?

Options:

A.  

1

B.  

2

C.  

3

D.  

4

Discussion 0
Questions 27

You are protecting a volume using the wizard in Unisphere for RecoverPoint. Which state will the new Consistency Group be in immediately after completing the wizard?

Options:

A.  

Initializing

B.  

Active

C.  

Paused

D.  

Disabled

Discussion 0
Questions 28

Which journal action available in Unisphere for RecoverPoint will NOT result in a full sweep synchronization and the loss of all history in the existing journal?

Options:

A.  

Add a journal volume

B.  

Remove a journal volume

C.  

Expand a journal volume

D.  

Reduce a journal volume

Discussion 0
Questions 29

An administrator experiences a serious error with an RPA and calls EMC Support to resolve the issue. They are concerned that the system did not automatically notify EMC Support via the ESRS gateway. You check all settings in Unisphere Configure System Notification and find they are correct.

What is the most likely cause for this notification failure?

Options:

A.  

TCP port 25 blocked at their firewall

B.  

TCP port 989 blocked at their firewall

C.  

TCP port 990 blocked at their firewall

D.  

Temporary remote support license key expired

Discussion 0
Questions 30

Which RecoverPoint CLI command would you run to get the errors and warnings for one cluster or for the entire environment?

Options:

A.  

get_system_status

B.  

get_rpa_states

C.  

get_groups

D.  

get_clusters_topology

Discussion 0