RecoverPoint Specialist Exam for Implementation Engineers
Last Update May 5, 2024
Total Questions : 200
We are offering FREE E20-375 EMC exam questions. All you do is to just go and sign up. Give your details, prepare E20-375 free exam questions and then go for complete pool of RecoverPoint Specialist Exam for Implementation Engineers test questions that will help you more.
A Consistency Group consists of one production copy, one local copy, and two remote copies.
How many journals are required for this configuration?
You are working on a RecoverPoint local replication solution in an environment that includes VNX and VMAX storage arrays. You want to create a Consistency Group (CG) for your Oracle database. However, some of the database volumes are located in the VNX and others are located in the VMAX.
What is the recommended management solution?
A large data center is hosting storage protection solutions for multiple companies. This solution is accomplished by the hosting organization's ability to consolidate data to an environment with two VNX arrays.
How many RecoverPoint clusters can be used in this environment?
You are a storage administrator tasked with creating a Consistency Group in a RecoverPoint/EX system. You launch the Protect Volumes wizard in Unisphere and notice that the desired production volume is not available.
What would be a possible cause?
Which tool do you need in order to run the save_settings command from a Windows command prompt?
A company has a DR site connected using a 4 Gbps FC link and two RPAs on the primary site, and two RPAs at the DR site. They are experiencing high load events although the FC link is not fully utilized.
What would be the best solution to get the FC link utilization up as high as possible?
What zoning must be created in the fabric when implementing a VMAX splitter?
What is the maximum number of copies supported using the MetroPoint topology for VPLEX continuous data replication?
In a EMC RecoverPoint environment, which EMC product adds support for heterogeneous storage systems?
A company is currently using RecoverPoint/CL with CLARiiON CXs in their environment. All of the data has been migrated to new VNXs and the CX splitters need to be removed from RecoverPoint.
How is this accomplished?
Which ports from a VPLEX Metro system must be zoned to the RPAs in order to install the VPLEX write splitter?
A company is using an EMC VNX storage array. RecoverPoint is being configured to replicate to a DR site. RP will be protecting three datastores:
How much of the user data is being replicated to the DR site?
When RecoverPoint is deployed with a VMAX splitter, what presents the virtual target and virtual remote devices?
During a failover event, you have determined that the last bookmark had corrupted data. What is the fastest way to find the last good replica?
An existing RecoverPoint/CL environment consists of one cluster at the main office and two off-site DR clusters. You have been asked to expand the environment to the maximum number of DR sites using RecoverPoint.
How many additional clusters could be added to this RecoverPoint Environment?
After expanding to include an additional existing RecoverPoint cluster you use Deployment Manager to connect the clusters, but it fails.
What might be the problem?
For optimal performance when presenting gatekeepers for a VMAX splitter, how many FA ports should be used in each port group?
After running a log collection, which user should you log in as to download the output file?
You are using the Test a Copy wizard and have chosen virtual access to test your database upgrade. The image has been mounted to a test host. While testing the database upgrade, the host loses access to the image.
What can you do to avoid this problem in the future?
A customer has two VMAX arrays and three VNX arrays fronted by an EMC VPLEX. They wish to use RecoverPoint to protect their environment.
How many licenses, and of which type, would be required for their environment?
A company is currently using RecoverPoint/SE in their environment. They have purchased a VMAX which will be deployed to replace a VNX splitter at one site only.
What must be done before they can use the VMAX with RecoverPoint (RP)?
When registering the RPA with a VNX to enable a VNX splitter for RecoverPoint, what failover mode must be set on the VNX?
You are protecting a volume using the wizard in Unisphere for RecoverPoint. Which state will the new Consistency Group be in immediately after completing the wizard?
Which journal action available in Unisphere for RecoverPoint will NOT result in a full sweep synchronization and the loss of all history in the existing journal?
An administrator experiences a serious error with an RPA and calls EMC Support to resolve the issue. They are concerned that the system did not automatically notify EMC Support via the ESRS gateway. You check all settings in Unisphere Configure System Notification and find they are correct.
What is the most likely cause for this notification failure?
Which RecoverPoint CLI command would you run to get the errors and warnings for one cluster or for the entire environment?