VPLEX Specialist Exam for Implementation Engineers
Last Update Apr 28, 2025
Total Questions : 210
We are offering FREE E20-260 EMC exam questions. All you do is to just go and sign up. Give your details, prepare E20-260 free exam questions and then go for complete pool of VPLEX Specialist Exam for Implementation Engineers test questions that will help you more.
Refer to the exhibit.
You are preparing to perform an upgrade on an unconfigured VPLEX Metro. When you run the ndu pre-check command, it indicates that it has failed and there are no first upgraders. In your troubleshooting, you run the version -a command.
Based on the output, what is the reason for the failure?
You need to claim storage that is presented to VPLEX from a VNX. What is required in order to create the mapping file needed by the VPLEX Claim Storage Wizard?
What is the purpose of I/O module 2 in a the VPLEX VS2 hardware configuration?
In a customer's VPLEX Metro environment, a host has been provisioned as a single virtual volume from cluster-1. The customer now needs to convert the local virtual volume to a distributed device.
How can the customer accomplish this?
Refer to the exhibit.
A customer is requesting a performance analysis for their distributed volumes in a Metro configuration to ensure there are no issues with a recent implementation.
What additional files should be collected?
Refer to the exhibit.
After a power disruption of 20 seconds in a VPLEX environment, the output of the "vault status" command shows no vaulting processes.
Why did this occur?
In a customer's VPLEX Metro environment, a host has been provisioned as a single virtual volume from cluster-1. The customer now needs to convert the local virtual volume to a distributed device.
How can the customer accomplish this?
What is EMC's best practice for fault tolerance when zoning a VPLEX Metro together over fibre channel for successful communication between the sites?
Which command script must be executed when upgrading a small VPLEX to medium VPLEX?
Which is a best practice recommended for VPLEX Metro inter-cluster WAN settings?
When creating logging and metadata volumes, which LUN requirement applies to both?
When configuring a VPLEX local cluster, according to EMC best practices, how many metadata volumes are required?
Following EMC best practices, what information is required to register a VPLEX on an ESRS portal?
A customer has a VPLEX Metro configuration across two data centers 200 km apart. During an overnight backup, the WAN-COM link between the two data centers fails.
Which volume allows for future incremental re-synchronization with the remote mirror once the link is restored?
VPLEX ndu pre-check command reports a time drift between directors and the Management Server. How must the NDU be performed?
A customer has purchased a dual engine VPLEX Metro cluster. During installation, there are not enough free SAN ports to connect all WAN-COM ports to the SAN. What is the recommended approach?
Refer to the exhibit.
What is the function of the two highlighted VPLEX VS2 modules?
A customer has ordered a two-engine VPLEX cluster to be installed in a custom rack. A minimal VNX5300 is already installed in the middle of the rack, occupying nine rack unit spaces.
What is the correct approach to deploy the two-engine VPLEX cluster?
Which unique logical identifier is used when determining the relationship between a virtual volume and the back-end storage array?
A dual fan failure occurs on a single VPLEX engine.
What will be the result?
Which is the best way to identify the root cause of long read latencies using monitors?
You are using VPLEX Unisphere to perform management functions in your environment. You are tasked with creating several volume migrations to a new storage array.
What tab should you use to perform this migration?
What is the EMC best practice for the optimum number of back-end storage paths per director presented to a LUN?
What is the total number of available engines in the smallest VPLEX Metro configuration?
A customer wants to implement VPLEX between two datacenters 200 km apart. The latency between the sites is 15 ms.
Which VPLEX topology is recommended?
Click on the calculator in the upper left corner. How much distributed storage can be managed by a 20 GB logging volume?