Easter Sale Special 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: exams65

Specialist - Platform Engineer PowerStore Exam Question and Answers

Specialist - Platform Engineer PowerStore Exam

Last Update May 16, 2024
Total Questions : 96

We are offering FREE DES-1241 EMC exam questions. All you do is to just go and sign up. Give your details, prepare DES-1241 free exam questions and then go for complete pool of Specialist - Platform Engineer PowerStore Exam test questions that will help you more.

DES-1241 pdf

DES-1241 PDF

$35  $99.99
DES-1241 Engine

DES-1241 Testing Engine

$42  $119.99
DES-1241 PDF + Engine

DES-1241 PDF + Testing Engine

$56  $159.99
Questions 1

A Storage Administrator wants to upgrade a two appliance Dell EMC PowerStore cluster. Which Commit options need to be chosen to have all appliances upgraded in the last step?

Options:

A.  

Appliance, Cluster

B.  

Appliance, Appliance

C.  

Cluster, Appliance

D.  

Cluster, Cluster

Discussion 0
Questions 2

In an unpopulated rack, at what U mark is the base enclosure racked?

Options:

A.  

3

B.  

4

C.  

2

D.  

1

Discussion 0
Questions 3

What describes Dell EMC PowerStore heat dissipation?

Options:

A.  

X systems have higher heat dissipation specifics than T systems

B.  

Higher model numbered systems have lower heat dissipation specifications than lower model numbered systems

C.  

T systems have higher heat dissipation specifics than X systems

D.  

Lower model numbered systems have lower heat dissipation specifications than higher model numbered systems

Discussion 0
Questions 4

A Storage Administrator ran a PSTCLI command on a Linux host. The error " -bash: pstcli: command not found" appears. How is the problem resolved?

Options:

A.  

Add the installation directory to the PATH variable on shell initialization file

B.  

Install in default directory /opt/dellemc/pstcli-version/bin/

C.  

Add /opt/dellemc/pstcli/bin/ in PSTCLI.sh

D.  

Run rpm -ihv pstcli to reinstall the PSTCLI software on the Linux host

Discussion 0
Questions 5

Which option is used when running the journalctl command to query log messages regardless of capitalization?

Options:

A.  

option --casesensitive=YES/NO

B.  

option -quotes

C.  

option -ignorecase

D.  

option --casesensitive=TRUE/FALSE

Discussion 0
Questions 6

Which component is only replaceable by qualified personnel?

Options:

A.  

Battery backup unit

B.  

Embedded I/O module

C.  

Memory module

D.  

4-Port mezzanine card

Discussion 0
Questions 7

Refer to the exhibit.

What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?

Options:

A.  

VLAN 1 and VLAN 1501 pass tagged traffic

B.  

VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic

C.  

VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic

D.  

VLAN 1 and VLAN 1501 pass untagged traffic

Discussion 0
Questions 8

What does the output of the PSTCLI command “nas_server show” display from a Dell EMC PowerStore T?

Options:

A.  

If NAS servers are present if they are either NFS or Licensed

B.  

Memory utilization and thread count for NFS NAS servers

C.  

If NAS servers are present and if they are either Started or Degraded

D.  

SIDs of SMB NAS servers joined to the AD Domain

Discussion 0
Questions 9

What does the command “svc_journalctl | grep ‘Mar 25 23:00’” do?

Options:

A.  

Ignores log messages from the specified date

B.  

Retrieves log messages from the specified date

C.  

Deletes all logs before the specified date

D.  

Rotates the log based on the specified date

Discussion 0
Questions 10

When planning for a Dell EMC PowerStore T implementation, how many IP addresses are required for the storage network?

Options:

A.  

2

B.  

1

C.  

3

D.  

4

Discussion 0
Questions 11

When looking at the base enclosure front view, what does a solid amber drive LED indicate?

Options:

A.  

Discover new drive

B.  

Rebuild activity

C.  

Faulted drive

D.  

Normal activity

Discussion 0
Questions 12

How is a defective embedded module displayed in Dell EMC PowerStore Manager?

Options:

A.  

Orange with an empty state

B.  

Orange with a faulted state

C.  

Blue with a faulted state

D.  

Blue with an empty state

Discussion 0
Questions 13

What is the result of setting a VLAN ID of 0 on a network when running ICW for Dell EMC PowerStore?

Options:

A.  

Network will pass tagged traffic

B.  

Static route is set

C.  

Network will pass untagged traffic

D.  

Default route is set

Discussion 0
Questions 14

How many nodes are in the base enclosure?

Options:

A.  

2 nodes configured as Active-Standby

B.  

1 node with duel connectivity

C.  

1 node with high availability enabled

D.  

2 nodes configured as Active-Active

Discussion 0