Questions 1

Which of the following are the user roles of Power Partner?

Options:

A.  

Service manager of a rep office

B.  

Startup engineer

C.  

Inventory operations manager

D.  

Project manager

E.  

DOC

F.  

Service engineer

Discussion 0
Questions 2

In a data center fire protection design, which approach best matches Huawei facility practice for protecting IT rooms while minimizing secondary damage to IT equipment?

Options:

A.  

Use only portable extinguishers and rely on manual response

B.  

Deploy a smoke detection system plus a clean-agent gas extinguishing system with interlock controls for automatic release

C.  

Install a water sprinkler system as the only suppression method inside the IT white space

D.  

Disable automatic suppression to avoid accidental discharge

Discussion 0
Questions 3

What is the upstream input voltage range of the UPS5000-H?

Options:

A.  

360 V–600 V

B.  

220 V–240 V

C.  

380 V–415 V

D.  

138 V–485 V

Discussion 0
Questions 4

On the ECC800-Pro WebUI, the PUE configuration mode can be "Standard" or "User-defined".

Options:

A.  

True

B.  

False

Discussion 0
Questions 5

The NetEco northbound interface does not support the SNMP protocol. Only WebService interfaces are supported.

Options:

A.  

True

B.  

False

Discussion 0
Questions 6

Which strategy most directly improves data center energy performance without compromising reliability when properly engineered and monitored?

Options:

A.  

Oversize all cooling and power equipment permanently to avoid future upgrades

B.  

Use higher allowable supply air temperature with containment and adaptive control to reduce compressor and fan energy

C.  

Disable alarms to reduce nuisance notifications and operator workload

D.  

Operate all redundant systems at full load simultaneously to maximize utilization

Discussion 0
Questions 7

The rated output capability of a single power module for the UPS5000-H is how many kVA.

Options:

A.  

50

B.  

100

C.  

30

D.  

60

Discussion 0
Questions 8

Which of the following statements are true about the routine maintenance of a UPS?

Options:

A.  

Environment check: Check whether the temperature and humidity of the equipment room meet the recommended environment requirements. Check whether the equipment room is clean and tidy.

B.  

UPS status check: Check whether the UPS works in normal mode, whether an alarm is generated, and whether the UPS is in a proper load.

C.  

Routine maintenance of vulnerable components: Periodically check the UPS fan operation, whether there is noise, and whether the rotation speed is abnormal.

D.  

If there is no alarm on the UPS panel, do not need to check the installation environment, temperature, and humidity onsite.

Discussion 0
Questions 9

ECO mode is not recommended when the load is less than

Options:

A.  

10%

B.  

30%

C.  

5%

D.  

20%

Discussion 0
Questions 10

The NetEco can be deployed on any virtualization platform.

Options:

A.  

True

B.  

False

Discussion 0
Questions 11

Which of the following statements is false about how to start an electric heater?

Options:

A.  

If "Dehumidification & Low temperature heating" is selected, the electric heater determines whether to start based on the temperature requirements when the dehumidification or heating conditions are met.

B.  

When "Dehumidification heating" is selected, the electric heater determines whether to start based on the current temperature only when the dehumidification function is enabled.

C.  

When "Dehumidification heating", "Low temperature heating", or "Dehumidification & Low temperature heating" is selected, if the temperature in the equipment room is low, the air conditioner automatically starts the heating function to meet the temperature control requirements of the equipment room.

D.  

When "Low temperature heating" is selected, the electric heater determines whether to start only based on the temperature requirements no matter whether the dehumidification function is enabled.

Discussion 0
Questions 12

Which of the following conditions will not cause the wizard startup commissioning to fail?

Options:

A.  

The condensate pump is stuck.

B.  

The indoor fan 2 drive is faulty.

C.  

The electronic expansion valve is not opened.

D.  

The water leakage rope is not installed.

Discussion 0
Questions 13

In IT scenarios, which of the following are the power supply and distribution components of the FusionDC1000A?

Options:

A.  

SmartLi

B.  

Power PDB

C.  

Integrated UPS

D.  

AC/DC power system

Discussion 0
Questions 14

The frequency of power supply equipment can be 50 Hz, 60 Hz, or 70 Hz.

Options:

A.  

True

B.  

False

Discussion 0
Questions 15

What are the colors of indicators on the LCD panel of the MDU?

Options:

A.  

Yellow

B.  

Green

C.  

Red

D.  

Orange

Discussion 0
Questions 16

Which of the following statements are true?

Options:

A.  

When the UPS works in normal mode, you can directly turn on the maintenance bypass switch.

B.  

When the UPS works in static bypass mode, if the mains input outage occurs suddenly, the UPS automatically switches to battery mode.

C.  

Huawei UPS5000-H is a modular UPS. If a module fails, it can be replaced online.

D.  

When mains and bypass input of the UPSs share one power source, if mains outage occurs, the UPS cannot work in bypass mode.

Discussion 0
Questions 17

After replacing the fan, choose "Menu > _____ > Performance Maintenance" on the main screen to enter the "Performance Maintenance" screen and clear the accumulated runtime of the indoor fan.

Options:

A.  

Alarms

B.  

Settings

C.  

Running

D.  

Maint

Discussion 0
Questions 18

During routine maintenance of the lithium battery cabinet, which of the following areas should be protected from electric shocks caused by exposed hands or metal objects?

Options:

A.  

Battery general positive terminal

B.  

Battery negative terminal

C.  

Short-circuit copper bar between battery modules

D.  

Battery positive terminal

E.  

Battery general negative terminal

Discussion 0