HCS-Pre-sales-Digital Power V1.0
Last Update May 4, 2024
Total Questions : 653
We are offering FREE H19-371_V1.0 Huawei exam questions. All you do is to just go and sign up. Give your details, prepare H19-371_V1.0 free exam questions and then go for complete pool of HCS-Pre-sales-Digital Power V1.0 test questions that will help you more.
When the distance between the outdoor unit and the seaside is 0.5km~3.7km, you need to configure the () outdoor unit
In FusionModule2000, how to adapt the skylight when the column occupies the closed passage space in the scene around the column?
The high input power factor of the UPS indicates that the UPS has a strong ability to effectively utilize the power grid and a weak ability to interfere with the power grid. The input power factor
of UPS2000-A-(1K-3K) is ( ).
Which mode does Fusi onllodul e800 air conditioner configuration support? ()
For UPS of 30.2+1 parallel system, the maximum load capacity allowed by the system is () times that of a single unit.
Huawei FusionPower6000 is used with which of the following UPS products ().
Relevant standards stipulate that the voltage drop of the AC cable needs to be controlled within 3%, and it is recommended that the voltage drop of the AC power edge be controlled within ( ) when designing the UPS system. /
The UPS5000-E has the function of adjusting the number of battery cells, which avoids the failure of a single battery to cause the replacement of the entire group, and solves the problem of difficult maintenance of
traditional UPS batteries. May I ask how many cells can be adjusted in the UPS5000-E (50kVA module)? ()
NetEco. supports northbound integration, which of the following is not currently supported? ( ).
In which of the following areas does the AHU scheme have the worst application effect (
Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, each rack has 3 groups of batteries, each group is 40, and the
capacity of the main switch box is ( )
The minimum ambient temperature used by FusionModule800 and FusionModule500 is ( ).
The type of circuit breaker used in the sub-circuit of the PDU8000 precision power distribution cabinet. ()
When a system is configured with 1H battery backup time, the discharge termination voltage of the battery cell should be selected as ( ).
UPS2000-G-(6K-20K) has a strong lightning protection design in the industry, lightning protection level (), surge protection level 0), which can avoid 90% failures caused by lightning strikes and
reliably protect the back-end equipment. AC input port.
The description of the bypass overload capacity of UPS5000-E is correct ( )
Which are standard configurations in the typical configuration of FusionModule500?
NetEco6000 management system uses the above security mechanisms to ensure network security and prevent the leakage of business sensitive data? (multiple choice)
The difference between traditional power frequency machine and high frequency machine is: () (multiple choice)/
FusionModule1000A V2R3 version 20 feet CT scene air conditioning features are (multiple choice)
Which of the following alarm functions does the PDU8000 precision power distribution cabinet branch circuit have: (multiple choice)
What certifications do Huawei precision column cabinets have (multiple choice)
What is the correct function description of the intelligent micro-module iPower of Fusionllodule2000 v3.0 version?
The circuit breaker of ( ) pole is generally used for the external maintenance bypass of the UPS system.
Regarding the monitoring software NetEco1000U, the following statements are correct ()
Which of the following models has the widest input voltage range and is more suitable for harsh power grids? (
Which of the following are the working modes of UPS2000-A-(1K-10K)? () (multiple choice)
U-position self-identification technology is used to ensure accurate placement of IT equipment. Which feature of NetEco is this?
The UPS5000-E power chess block adopts the fan fault-tolerant design. When one of the fans is damaged, what percentage of the load can the power module still carry? ( )
UPS5000-E about the characteristics of intelligence, which are correct? ()
According to the ICT Research 2018 statistical report, the market share of Huawei's line-level temperature control products in China in 2017 is: ()
Huawei Technologies Co., Ltd. is GB50174-2008 standard () is GB50174-2017 standard /
The asset management in the NetEco management system can manage the asset information of which of the following devices to realize the life cycle management of assets? (multiple choice)
Huawei's modular computer room supports cold aisle and hot aisle. True or False.
Which of the following alarm functions does the PDU8000 precision power distribution cabinet branch circuit have:
FusionModule1000A V2R3 version 20-foot CT solution supports a maximum CT load of 8kW /
The smoke sensor used in the NetEco6000 management system cannot replace the smoke sensor in the fire protection system. ( ).
NetEco6000 management system can realize APP + intelligent inspection, greatly reducing operation and maintenance man-hours
Huawei Netcol air-cooled air conditioner requires low temperature components when the outdoor temperature is lower than -20"C ()
FusionModule500&FusionModule800 remote web interface monitoring must be configured with unified network management software ( ).
The capacity management module of the NetEco management system can connect with third-party () systems, accept equipment change information, automatically generate a change application form and track the processing process?
UPS5000-E 100KVA, the input switch to be selected by the machine, which of the following is the most suitable ( )
FusionModule2000 - The integrated UPS supports a maximum of 6 25KVA power modules.
UPS5000-E (50kVA power modules) 150kVA, rack 1+1 redundancy, in the total input cabinet, the required total input switch is ()
UPS5000-A can significantly reduce the harmonic pollution to the power grid. In the case of linear full number, the input electric-hydrodynamic distortion nmi is ().
What is the maximum IT load supported by the FusionModule2000 integrated UPS?
Regarding the FusionModule2000 wiring, which of the following statements is wrong?
FusionModule supports access control by swiping card, but does not support two-way card swiping. ( ). /
The RS485 expansion card in the ECC500 collector can provide 5 RS485 interfaces, and each interface can provide 12V DC output.
When choosing a 300mm air conditioner, you need to choose a 300mm control skylight ( )
To configure a modular redundant UPS system, as long as the number of modules meets the basic requirements, there is no need to consider the distribution of UPS modules on different racks.
FusionModule2000 does not support the configuration of sliding doors/electric doors in a single-row cabinet scenario
NetCol air conditioner 35kW/46kW supports linkage control of internal and external units ( ).
UPS2000-G - The card monitors the entire parallel system, and the parallel system only needs one communication option card to monitor the entire parallel system.
Huawei Precision Air Conditioner supports 1 indoor unit corresponding to multiple outdoor units (true or false).
The PDU8000 precision power distribution cabinet adopts a 7-inch liquid color touch screen, which can graphically display the system diagram of the power distribution cabinet and the status of each switch.
Configure the UPS system plan, which of the following factors need to be considered in the calculation plan: ()
The national public security will establish three cloud computing centers at the ministry, province and city levels.
In a data center scenario, it is common to have multiple gates in a room. Therefore, in order to reduce the cost of the whole solution, the NetEco6000 management system adopts four-door
access control box by default. ( ).
The use of IGBT rectifier high-frequency machine, compared with SCR rectifier power frequency machine, can significantly reduce the harmonics of the input current and improve the input power factor.
Air conditioning water systems include cooling water systems, chilled water systems and condensate water systems.
Which of the following statements about wet film humidification is correct? ( ).
Regarding the Fusionlodule2000 wiring, which of the following statements is wrong?
The asset management module of the NetEco management system supports which of the following parameters can be used to quickly search for asset information? (Multiple choice)
The new room-level air-cooled series is based on the indoor return air of 35C and the outdoor temperature of 35C. The cooling section has ( )
Which of the following accessories in FM2000 can be adjusted in quantity ( ). /
The NetEcoo6000 management system can provide monitoring of the cooling power system, and which of the following functions can it provide? (Multiple choice)
Why are FusionModule500&FusionModule800 generally recommended to customers for typical configuration solutions? (Multiple choices)
Huawei 25KW half-cabinet inverter air-cooled air conditioner, the following description is correct (multiple choice)
Regarding the cabinet rPDU of FusionModule2000, which of the following statements is wrong?