Questions 1

Two tents which each have an area of 20,000 sq. ft. shall be separated from each other by a distance of not less than:

Options:

A.  

0 ft. (no separation is required).

B.  

10 ft.

C.  

20 ft.

D.  

25 ft.

Discussion 0
Questions 2

When more than 500 chairs are used for an assembly event held in a gymnasium, they must be secured to the floor or:

Options:

A.  

be spaced at least 6 in. apart.

B.  

be fastened together in groups of not less than 3.

C.  

be fastened together in groups of not less than 6.

D.  

be fastened together in groups of not less than 10.

Discussion 0
Questions 3

A bowling center with 25 lanes and 3,500 sq. ft. of additional area calculates to a maximum occupant load of how many people?

Options:

A.  

125

B.  

234

C.  

500

D.  

625

Discussion 0
Questions 4

Blocks or piles of baled fiber shall be separated from adjacent storage by aisles which are not less than __ ft wide

Options:

A.  

3

B.  

5

C.  

8

D.  

10

Discussion 0
Questions 5

Fine magnesium scrap stored in quantities greater than 1,000 cu. ft. shall be separated from all buildings other than those used for magnesium scrap recovery operations by a distance of not less than ___ ft.

Options:

A.  

30

B.  

50

C.  

100

D.  

250

Discussion 0
Questions 6

Keys necessary for the unlocking of exit doors must be individually identifiable by both sight and touch in which of the following occupancies?

Options:

A.  

Group A occupancies

B.  

Group E occupancies

C.  

Group I occupancies

D.  

Group R occupancies

Discussion 0
Questions 7

What is the maximum number of students permitted in a classroom that measures 20 ft. x 30 ft., and which contains four fixed 4 ft. x 8 ft. tables?

Options:

A.  

12

B.  

24

C.  

30

D.  

40

Discussion 0
Questions 8

Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with

Options:

A.  

UL 1975

B.  

NFPA 11A

C.  

CPSC 16CFR

D.  

ASTM D 1784

Discussion 0
Questions 9

Extra-high-rack combustible storage is defined in the fire code as any storage on racks of Class I, II, III, or IV commodities which exceed ___ ft. in height, and any storage on racks of high-hazard commodities which exceed ___ ft. in height.

Options:

A.  

20; 30

B.  

30; 40

C.  

40; 30

D.  

50; 40

Discussion 0
Questions 10

Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.

Options:

A.  

55

B.  

100

C.  

250

D.  

500

Discussion 0
Questions 11

Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?

Options:

A.  

They become a public record.

B.  

They are time-consuming to complete and file.

C.  

They may not address all of the code violations which may be encountered.

D.  

They may serve as a basis for legal appeal against the code official's actions.

Discussion 0
Questions 12

The interior finish of walls and a ceiling in an atrium may not be less than __ Class

Options:

A.  

A

B.  

B

C.  

C

D.  

D

Discussion 0
Questions 13

All new building construction must have installed an approved water supply for fire protection which provides a minimum of:

Options:

A.  

the required fire flow for fire protection.

B.  

a static pressure of 40 psi at each hydrant.

C.  

a static pressure of 60 psi at each hydrant.

D.  

250 gal. per minute at the fire-access outlet.

Discussion 0
Questions 14

A building under construction which has two stairways shall have a minimum of how many fire extinguishers per floor?

Options:

A.  

1

B.  

2

C.  

3

D.  

4

Discussion 0
Questions 15

In a control area where flammable liquid storage containers are in piles, there shall be a minimum of __ in. of clearance between the top of the storage and the deflector or discharge orifices of a sprinkler system.

Options:

A.  

18

B.  

24

C.  

30

D.  

36

Discussion 0
Questions 16

The fire code official has the right to enter a building to perform inspections in all of the following situations except:

Options:

A.  

vacant buildings at any time.

B.  

factory floors with permission to enter.

C.  

public spaces of a mall during normal business hours.

D.  

interior space of a warehouse with an administrative warrant.

Discussion 0
Questions 17

When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.

Options:

A.  

50

B.  

75

C.  

100

D.  

150

Discussion 0
Questions 18

Fire inspectors receiving citizen complaints about a building should first:

Options:

A.  

record all pertinent information.

B.  

investigate the history of the building.

C.  

forward the complaint to the senior inspector.

D.  

inform the owner of the building that a complaint has been filed against him.

Discussion 0
Questions 19

A local board of appeals may perform all of the following functions except:

Options:

A.  

waive requirements of the fire code.

B.  

render interpretations of the fire code.

C.  

approve alternate materials and types of construction.

D.  

adopt rules and regulations for conducting its investigations.

Discussion 0
Questions 20

When investigating a complaint of a violation within an occupied public area, the fire inspector:

Options:

A.  

must give prior notice to the occupant.

B.  

need not give prior notice of the inspection to the occupant.

C.  

must provide the occupant with at least 24 hours of advance notice.

D.  

must either give prior notice to the occupant or obtain an inspection warrant.

Discussion 0
Questions 21

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.

Options:

A.  

735

B.  

1,000

C.  

2,000

D.  

2,500

Discussion 0
Questions 22

A 501 gal. water capacity above-ground liquefied petroleum gas (LP-gas) tank located 20 ft. from a 250 gal. LP-gas tank must be separated a minimum of __ ft. from adjoining property.

Options:

A.  

5

B.  

10

C.  

20

D.  

25

Discussion 0
Questions 23

Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?

Options:

A.  

Group I-2

B.  

Group A-1

C.  

Office spaces

D.  

Libraries in Group E

Discussion 0
Questions 24

Given: A local college student inquires about the use of candles in their dorm room. Candles:

Options:

A.  

may not be used.

B.  

may be used in a sprinklered dormitory.

C.  

must be kept a minimum 12 in. from combustibles.

D.  

must be kept a minimum 36 in. from combustibles.

Discussion 0
Questions 25

Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.

Options:

A.  

12

B.  

18

C.  

24

D.  

36

Discussion 0
Questions 26

Clearance between tops of piles of combustible fibers and sprinkler heads shall not be less than ___ ft.

Options:

A.  

2

B.  

3

C.  

4

D.  

5

Discussion 0