Questions 1

When using the XtremIO PoC Toolkit, what is the purpose of the Age phase?

Options:

A.  

Continuously write to a specific range of logical block addresses to test Flash durability

B.  

Overwrite each LUN multiple times to ensure they contain all unique data

C.  

Test the performance of the All-Flash array with non-production static data

D.  

Scatter writes across the entire array to simulate ordinary use of the system

Discussion 0
Questions 2

A customer is considering a six brick dispersed cluster using 3×40U racks. The customer wants advice on racking the InfiniBand switches.

  • Rack 1 (left) contains X-Bricks 1 and 2
  • Rack 2 (middle) contains X-Bricks 3 and 4
  • Rack 3 (right) contains X-Bricks 5 and 6

Which recommendation should be provided?

Options:

A.  

Install the InfiniBand switches in Rack 1 with a 1U placeholder between the switches.

B.  

Install an InfiniBand switch in Racks 1 and 3 with a 1U placeholder between the X-Bricks.

C.  

Install the InfiniBand switches in Rack 2 with a 1U placeholder between the switches.

D.  

Install the InfiniBand switches in Rack 3 with a 2U placeholder between the switches

Discussion 0
Questions 3

When using a 10 TB single X-Brick, what is the minimum amount of data that should be written during the Fill phase of the PoC Toolkit?

Options:

A.  

10 TB

B.  

15 TB

C.  

20 TB

D.  

30 TB

Discussion 0
Questions 4

As shown in the exhibit, a customer’s environment is configured as follows:

  • Dual X-Brick cluster
  • 8 ESXi hosts with 2 HBAs
  • Each ESXi hosts has 8 LUNs
  • Each LUN is visible through 4 paths

What should be the host queue depth setting per path?

Options:

A.  

64

B.  

128

C.  

256

D.  

1024

Discussion 0
Questions 5

When creating XtremIO volumes for a host, which operating systems will benefit by changing the default logical block size for applications consisting of 4 KB I/Os?

Options:

A.  

Microsoft Windows and RHEL

B.  

VMware ESX and Microsoft Windows

C.  

RHEL and IBM AIX

D.  

Sun Solaris and HP-UX

Discussion 0
Questions 6

A physical XtremIO Management Server (XMS) has failed and requires replacement. Which two software packages are required for recovery?

Options:

A.  

XMS image and OVA image

B.  

Xtremapp and OVA image

C.  

XMS image and Xtremapp

D.  

Xtremapp and MPIO

Discussion 0
Questions 7

A customer has a large ESX server environment they are considering deploying to XtremIO for a VDI implementation. To determine a baseline of the environment, you are proceeding with documenting each server’s CPU, NIC, and disk utilization statistics. The customer has provided you with direct CLI access to the servers to conduct this assessment.

Which utility should be used to monitor these performance parameters?

Options:

A.  

esxtop

B.  

resxtop

C.  

top

D.  

iostat

Discussion 0
Questions 8

Based on XtremIO Data Protection, how many dedicated hot spare disks per X-Brick are required?

Options:

A.  

0

B.  

1

C.  

2

D.  

3

Discussion 0
Questions 9

An administrator receives an error on an XtremIO array while performing snapshot refreshes to a production volume. What is a potential cause for this issue?

Options:

A.  

Refresh of the production volume is not supported

B.  

Volume was not unmapped on the XtremIO cluster

C.  

Only snapshot-to-snapshot refresh is supported

D.  

Volume was not unmounted on the host

Discussion 0
Questions 10

You are designing an XtremIO solution for a potential customer. If the server and storage information is available, which information should be documented regarding the customer’s capacity expectations?

Options:

A.  

Capacity requirements on a per data center basis

Expandability/scalability

Performance requirements determined on a server-to-server basis

B.  

Capacity requirements on a per volume basis

Expandability/scalability

Performance requirements determined on a server-to-server basis

C.  

Capacity requirements on a per volume basis

Compression rates/scalability

Performance requirements determined on a server-to-server basis

D.  

Capacity requirements on a per data center basis

Expandability/scalability

Performance requirements determined holistically

Discussion 0