Easter Sale Special 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: exams65

Specialist - Implementation Engineer-SC Series Exam Question and Answers

Specialist - Implementation Engineer-SC Series Exam

Last Update May 15, 2024
Total Questions : 147

We are offering FREE DES-1721 EMC exam questions. All you do is to just go and sign up. Give your details, prepare DES-1721 free exam questions and then go for complete pool of Specialist - Implementation Engineer-SC Series Exam test questions that will help you more.

DES-1721 pdf

DES-1721 PDF

$35  $99.99
DES-1721 Engine

DES-1721 Testing Engine

$42  $119.99
DES-1721 PDF + Engine

DES-1721 PDF + Testing Engine

$56  $159.99
Questions 1

Which component of the Dell Storage Manager (DSM) Suite’s only purpose is to perform disaster recovery?

Options:

A.  

Dell Storage Manager Remote Data Collector

B.  

Dell Storage Manager Primary Data Collector

C.  

Dell Storage Manager Server Agent

D.  

Dell Storage Manager Client

Discussion 0
Questions 2

Refer to the Exhibit.

A customer needs your assistance in recovering files that were deleted from an SC Series array volume. The files were deleted around 1:00 AM on January 7th. Based on the exhibit of the Dell Storage Manager (DSM), which recommendation allows the customer to recover the most recent deleted files?

Options:

A.  

Take a manual snapshot and then select “Create Volume from Snapshot”

B.  

Select “Create Volume from Snapshot” taken on January 7 and map to a server

C.  

Recover from backup, deleted files are unrecoverable from the storage array

D.  

Select “Create Volume from Snapshot” taken on January 6 and map to a server

Discussion 0
Questions 3

You are required to install twenty-four (24) 3.5” 12 Gb disks on a deployed system. Which disk enclosure would support this?

Options:

A.  

SC420

B.  

SC400

C.  

SCv320

D.  

SC460

Discussion 0
Questions 4

Refer to the exhibit.

When scanning Fibre Channel on a QLogic HBA what information can be obtained?

Options:

A.  

The volume mapped to the QLogic HBA

B.  

WWN of the QLogic HBA

C.  

WWN of the connected Storage Center

D.  

WWN of the SAN switch

Discussion 0
Questions 5

What is the maximum number of Fault Domains on a SCv3000 Storage Center using SAS front-end?

Options:

A.  

1

B.  

2

C.  

3

D.  

4

Discussion 0
Questions 6

To achieve redundancy, how many connections from the same SC Series controller are required per fault domain?

Options:

A.  

1

B.  

2

C.  

3

D.  

4

Discussion 0
Questions 7

Based on best practices, which configuration represents how an SC9000 storage array with one SC420 expansion enclosure is cabled?

Options:

A.  

Option A

B.  

Option B

C.  

Option C

D.  

Option D

Discussion 0
Questions 8

Which command is used to set the eth0 IP address on an SC4020 controller?

Options:

A.  

ifconfig inet eth0 [IP address] [netmask] [gateway]

B.  

controller ipconfig eth0 [IP address/prefix length]

C.  

ifconfig inet eth0 [IP address/prefix length]

D.  

controller ipconfig eth0 [IP address] [netmask] [gateway]

Discussion 0
Questions 9

Which best practices should be followed when using iSCSI to connect SC Series arrays and hosts?

Options:

A.  

Use dedicated switches for iSCSI.Two separate VLANS for multipathed iSCSI using separate IP subnets.Gigabit full duplex between Storage Center and all local servers.

B.  

Use separate IP subnets for multipathed iSCSI separated by VLANS when using the same switch.Gigabit full duplex between Storage Center and all local servers

C.  

Use separate switches for iSCSI.Two separate VLANs for multipathed iSCSI using separate IP subnets.Unicast and multicast storm control enabled on all iSCSI switches.

D.  

Use separate VLANs for multipathed iSCSI using separate IP subnets when using the same switch.Bi-directional flow control disabled between Storage Center and servers.

Discussion 0
Questions 10

How many SC220 enclosures can be supported by an SC4020 storage array?

Options:

A.  

7

B.  

9

C.  

14

D.  

15

Discussion 0
Questions 11

Which user type can create and map volumes using servers and disk folders that have already been created?

Options:

A.  

FSE

B.  

Root

C.  

Reporter

D.  

Volume Manager

Discussion 0
Questions 12

Why would the Key Management Server (KMS) Settings page appear during installation?

Options:

A.  

Page appears only if SED drives are present

B.  

Page only appears if an external KMS is defined during setup and configuration

C.  

Page is standard and always appears as part of the installation and configuration

D.  

Page only appears if a security certificate is not generated

Discussion 0
Questions 13

When installing an SC Series array, the customer indicated that they want the controller configured to provide the maximum amount of storage space. You discover that the storage controller was shipped with twelve 900 GB drives and twelve 1.8 TB drives of the same type.

Which redundancy level can be selected to provide the maximum amount of storage?

Options:

A.  

Put equal size drives in their own pagepool.Change the default redundancy level for the 1.8 TB drives.

B.  

Put all drives in the same tier.Keep the default redundancy level for both the 900 GB and 1.8 TB drives.

C.  

Put equal size drives in their own tier.Change the default redundancy level for the 900 GB drives.

D.  

Put equal size drives in their own pagepool.Keep the default redundancy level for both the 900 GB and 1.8 TB drives.

Discussion 0
Questions 14

What type of Host connectivity is required for Live volume?

Options:

A.  

FCoE

B.  

MPIO

C.  

TOE Host Bus Adapter

D.  

Target Initiator to the Primary system

Discussion 0
Questions 15

Based on documented best practices, which options may need to be modified on a server QLogic HBA?

Options:

A.  

Port Down Retry Count and Enable LIP Reset

B.  

Enable Target Reset and Login Retry Count

C.  

Port Down Retry Count and Enable Target Reset

D.  

LUNs Per Target and Port Down Retry Count

Discussion 0
Questions 16

After the implementation of a DR site with Synchronous replication all applications were up and running fine. The restore points were saved and validated; DR was predefined and successfully tested. Sometime later, one of the applications became unresponsive and initial troubleshooting points to Storage/Volume as the root cause.

Concerning the Replication to the DR site, what could be happening?

Options:

A.  

Customer must switch to asynchronous replication as volumes tied to applications should not be synchronous replicated.

B.  

The synchronous replication has been set to High Consistency and the link between the two sites is down.

C.  

Unresponsive applications cannot be related to any DR or Replication practices

D.  

Only asynchronous replication can possibly have a negative impact to volumes and applications if the link is down

Discussion 0
Questions 17

A customer wants to add an iSCSI path to a Microsoft Windows Server 2012 R1. The server has an existing Fibre Channel path to an SC7020 array for load balancing and high availability.

Which Windows MPIO policy should be configured to achieve the customer’s requirement?

Options:

A.  

Fail Over Only

B.  

Weighted Paths

C.  

Round Robin with Subset

D.  

Round Robin

Discussion 0
Questions 18

An SC9000 controller was rebooted to test failover and is back online. Do the controllers need to be rebalanced?

Options:

A.  

Yes; however, the other controller needs to be rebooted first

B.  

No; this is done automatically as part of the reboot process in DSM

C.  

No; they are automatically rebalanced on the SC9000

D.  

Yes; this can be done from the Summary, Storage, or Hardware tab in DSM

Discussion 0
Questions 19

Which SC Series array feature simplifies iSCSI connectivity and allows access to all ports through redirection?

Options:

A.  

Legacy Port Mode

B.  

ISNS

C.  

ALUA

D.  

Virtual Port Mode

Discussion 0
Questions 20

Which component of the Dell Storage Manager (DSM) suite’s only purpose is to perform disaster recovery if the primary data collector is no longer available?

Options:

A.  

Dell Storage Manager Client

B.  

Dell Storage Manager Server Agent

C.  

Dell Storage Manager Remote Data Collector

D.  

Dell Application Protection Manager

Discussion 0
Questions 21

What is used for migrating data from legacy system volumes to SC default provisioned volumes?

Options:

A.  

Thin Import

B.  

Intelligent Import

C.  

Thick Import

D.  

Live Migration

Discussion 0
Questions 22

A customer is concerned they are over utilizing their 7K drives. Where can information about the real time I/O usage of individual drives be viewed?

Options:

A.  

Hardware > Disks > [disk folder] > [disk number]

B.  

Charting > Disks > [disk folder] IO Charts

C.  

Charting > Disks > [disk folder] > [disk number]

D.  

Hardware > Disks > [disk folder]

Discussion 0