EXIN EPI Certified Data Centre Specialist
Last Update Mar 25, 2025
Total Questions : 60
We are offering FREE CDCS Exin exam questions. All you do is to just go and sign up. Give your details, prepare CDCS free exam questions and then go for complete pool of EXIN EPI Certified Data Centre Specialist test questions that will help you more.
It is assumed that EMF shielding material must be installed as the EMF levels coming from the transformer room into the computer room are measured at 100mG. The transformer room is approximately 10 meters away from the computer room and is separated by a corridor. You can assume that no physical issues are present for installing shielding material at any area/location.
Where should you recommend the shielding material to be installed?
In which stage of the data center life cycle does commissioning take place?
The humidity in the computer room has changed from about 50% down to 35% Relative Humidity (RH).
What influence does this have on Electrostatic Discharge (ESD)?
You are allowed to use a calculator for this question.
A computer room has a net volume of approximately 2,500 m³ / 88,287 ft³.
The temperature is 20 °C / 68 °F.
The required design concentration is 7%.
The S-Factor is 0.1359 (metric) / 1.885 (imperial).
Calculate the amount of gas required for this computer room based on FM200. What is the correct weight?
You are installing new copper cabling.
What is the advantage or disadvantage of choosing pre-terminated category 6 or 6A cabling?
The temperature in the computer room is being increased from 18°C/64°F to 27°C/81°F.
What is the impact, if any, on the amount of gas required to suppress a fire assuming the gas is a Halocarbon?
From the options indicated, what is the correct starting point for the raised floor installation?
In order to save energy, you are going to install an automated system to switch off lights. What should be taken into consideration when installing such a system?
An air-conditioner unit needs to be selected. Two types are available:
Unit-A has a Sensible Heat Ratio (SHR) of 0.7.
Unit-B has a Sensible Heat Ratio (SHR) of 0.9.
From an efficiency point of view, which one should be selected?
You need to determine the strategy for the cooling audit. All the servers are based on a front-to-rear (F-R) airflow design.
Which location for the temperature/humidity measurement should you recommend for the audit?
What precaution shall be taken for cabling leading into an equipment rack when a data center is in a seismic-prone area?
A new network storage device in a non-standard size rack of approximately 600 kg/1,300 lbs is going to be installed in the data center.
Are new floor loading calculations required?
The electrical diagram of the data center shows the following UPS configuration and has a load of 80 kW.
What is the set-up in this data center?
When shielding material reaches its saturation point, what will be the impact?
What is a significant difference between a halocarbon gas-based fire suppression system and an inert gas-based fire suppression system?
The logical overview of the data center looks as pictured. To what TIA-942 Rating is this design made based on electrical only?