According to API RP 540, threaded conduit joints for explosionproof connections should be made with at least how many fully engaged threads?
What document provides information on design and installation of electrical systems for fixed and floating offshore petroleum facilities for unclassified and Class I, Zone 0, Zone 1 and Zone 2 locations?
According to API 541, when specified, shipping preparations shall make the equipment suitable for outdoor storage from the time of shipment for at least:
According to NETA, for low voltage cables a visual inspection must verify that:
According to API 541, exterior surfaces, with the exception of machined surfaces or corrosion resistant material, shall be coated with which of the following?
In a Class I hazardous area, what is the maximum distance from an enclosure, containing arcing devices should a conduit seal be located?
According to the guide definitions, a junction box used within a control building or instrument enclosure may also be referred to as an:
During transformer inspection, the source inspector should verify that alarm, control, and trip settings on temperature and level indicators are:
The primary purpose of the source inspection project plan is to provide the:
Areas where ignitable concentrations of flammable gases or vapors are present continuously or for long periods of time are classified as:
Before starting surveillance, the source inspector should confirm that the supplier/vendor has:
Which switchgear-related item is explicitly identified in the guide table of contents as an inspection topic?
Final inspection and shipping preparations of switchgear typically consists of verifying all of the following except:
According to NFPA 70, an insulated conductor used within a switchboard or switchgear shall be rated not less than the voltage applied to it and:
Which MCC feature is specifically listed in the guide as part of design/construction review?
According to API 541, totally enclosed machines TEFC, TEPV, TEWAC, and TEAAC are equipped with which of the following?
Which edition of industry codes and standards applies to the equipment being inspected?
According to NFPA 70, the number of bends permitted between pull points for rigid metal conduits RMC shall not be more than:
According to API 541, for the bearing temperature rise test, motor bearing stable temperature is defined:
Who should the Source Inspector notify if they believe that product quality may be compromised by schedule pressures?
In addition to purchase order requirements and company standards, what document would provide the details for correct coatings application?
Any reports, such as Material Test Reports, that have been modified or corrected should be:
According to NFPA 70, is the use of Teflon tape on threaded connections for conduits allowed?
According to API 541, determination of efficiency and power, locked-rotor current, power factor, torque, full-load current and slip are some of the tests verified when performing a:
Circuit breakers over 1000 V equipped with stored energy mechanisms shall perform which of the following functions?
What document is used for petroleum and chemical industry premium-efficiency, severe-duty, totally enclosed fan-cooled TEFC squirrel cage induction motors up to and including 370 kW 500 hp?
During the course of manufacturing the supplier/vendor may propose design changes that could impact cost, schedule and/or quality. In such cases, the source inspector should: